Certified reference materials for qualifying spectrophotometer as a complete set To maintain constant good measurement results, a regular review of the accuracy of the spectrophotometer is required. With the use of certified reference materials from Hellma Analytics, you make sure that your equipment qualifications meet the requirements of the pharmacopoeias and fulfill your internal quality requirements, at the same time you reach the international comparability of your measurement results. The certified reference materials (calibration standards) of the DIN EN ISO 17025 accredited Hellma Analytics calibration laboratory are traceable to the primary standards of NIST (National Institute of Standards and Technology) and meet the requirements of the major pharmacopoeias (e.g. EP, DAB, USP). Your benefits: -High quality of the measurement results -International comparability of measurement results -Meeting the requirements of the major pharmacopoeias (EP, DAB, USP) -Results traceable to NIST primary standards -30 years warranty* on the reference materials Scope of delivery: -Certified reference materials (Calibration Standards) in quality storage box -DAkkS Calibration Certificate (DIN 17025) -Handling guidelines Glass Filters: For testing spectrophotometers. Photometric accuracy and wavelength accuracy in the visible spectral region. Liquid Filters: For testing spectrophotometers according to European Pharmacopoeia, wavelength accuracy, photometric accuracy, stray light behaviour, resolution. Product Specification: Product Type: 666-S000 Description: Complete Set Glass Filters Capacity: 666-F1 666-F2 666-F3 666-F4 666-F0 Material: Holmium Oxide Glass Filter Neutral Density Glass Filter NG 11 Neutral Density Glass Filter NG 5 Neutral Density Glass Filter NG 4 Empty Filter Mount Wavelength: 279, 361, 453, 536, 638 440; 465; 546,1; 590; 635 440; 465; 546,1; 590; 635 440; 465; 546,1; 590; 635 nm | |
Catalogue Number | 9.190 973 |
Manufacturer | Hellma |
Manufacturer P/n | 666S000 |
Fisher Ref | 3076236 |
VWR Ref | HELL666-000-RE |
Capacity | 666-F1 666-F2 666-F3 666-F4 666-F0 |
Type | 666-S000 |
Material | Holmium Oxide Glass Filter Neutral Density Glass Filter NG 11 Neutral Density Glass Filter NG 5 Neutral Density Glass Filter NG 4 Empty Filter Mount |
Wavelength nm | 279, 361, 453, 536, 638 440; 465; 546,1; 590; 635 440; 465; 546,1; 590; 635 440; 465; 546,1; 590; 635 |
PK | 1 |
Thermo Fisher: | 3076236 |
VWR: | HELL666-000-RE |
- Laboratory > Optical instruments and Microscopes > Photometer > Spectrophotometers > Spectrophotometer Calibration Kits
- Chromatography > UV Vis Supplies > UV Cuvettes
- Laboratory > Optical instruments and Microscopes > Photometer > Glass Cuvettes > Certified reference materials for qualifying spectrophotometer as a complete set