Your basket is empty

Xylem - SI Conductivity Cell 4-pole LF 613T 285106131
Enlarge

Xylem - SI Conductivity Cell 4-pole LF 613T 285106131

PART NO: 4AJ-9041227
Price: €587.00
Out of Stock (Ships in approx. 2 weeks)

Conductivity Cell 4-pole LF 613T with temperature sensor and fixed cable 1m

Conductivity measuring cells
With plastic shaft and internal temperature sensor NTC30 kOhm, temperature range -5 to +80 °C. Cable with 8-pole plug.
-LF 435 T: Conductivity measuring cells with 4 electrode technique for a large measuring range of 5 µS/cm to 500 mS/cm, low maintanance and easy cleaning. For general measurements. With 1.5 m cable.
-LF 513 T: For field and laboratory measurments of 1µS/cm to 200 mS/cm. 2 electrode measuring technique with platinized ring electrodes. Easy cleaning through removable low shaft ending. With 1 m cable.
-LF 613 T: For field and laboratory measurments in a measuring range of 1µS/cm to 2000 mS/cm. Less polarisation effects through 4 electrode measuring technique with platinum ring electrodes. Easy cleaning through removable low shaft ending. With 1 m cable.

Conductivity measuring cells
With plastic shaft and internal temperature sensor NTC30 kOhm, temperature range -5 to +80 °C. Cable with 8-pole plug.

LF 435 T: Conductivity measuring cells with 4 electrode technique for a large measuring range of 5 µS/cm to 500 mS/cm, low maintanance and easy cleaning. For general measurements. With 1.5 m cable.
-Excellent linearity over a wide measuring range, especially for high conductivity values
-Easy cleaning
-Long term stable cell constant through abrasion resistant, concentric graphite electrodes
-Integrated temperature sensor with short response time for automatic temperature compensation
LF 513 T: For field and laboratory measurments of 1µS/cm to 200 mS/cm. 2 electrode measuring technique with platinized ring electrodes. Easy cleaning through removable low shaft ending. With 1 m cable.
LF 613 T: For field and laboratory measurments in a measuring range of 1µS/cm to 2000 mS/cm. Less polarisation effects through 4 electrode measuring technique with platinum ring electrodes. Easy cleaning through removable low shaft ending. With 1 m cable.

Product Specification:
Product Type: LF 613 T
Electrode: 4 Pt rings
Shaft diameter: 12 mm
Length: 120 mm
Cell constant: K=1.0

Catalogue Number9.041 227
ManufacturerXylem - SI
Manufacturer P/n285106131
Fisher Ref3427607
VWR Ref663-4006
TypeLF 613 T
Length mm120
Shaft diameter mm12
PK1
Cell constantK=1.0
Electrode4 Pt rings
Thermo Fisher:3427607
VWR:663-4006
Your basket is empty