Aqualytic Oxygen Meter SD 400 OXI L (Set2) 4740010
PART NO: 4AJ-6288679
Price: €1,048.30
Out of Stock (Ships in approx. 6 weeks)
Meter with 4 (AA) batteries, optical oxygen probe with 3 m cable, storage/calibration bottle, micro SD card with calibration data, software and manual (on Micro SD card), short manual and lanyard in case.
Newly developed oxygen meter for use in sewage and water works, research and teaching as well as in aquaristics. High measuring accuracy and low maintenance, thanks to luminescence technology no electrolyte solution is required. The SD 400 Oxi L is ideally suited for the determination of dilution BOD due to the optimized probe for standard BOD bottles.
- Especially high measuring accuracy by luminescence technology
- Short response time of the oxygen probe
- Low maintenance due to long-lasting oxygen probe and membrane head
- Inflow to the oxygen probe is not necessary, the use of stirrers or manual stirring is no longer required
- Includes software for extended and simplified data management with data logger function
- Backlit LC display for dark environments
Scope of delivery:
SD 400 Oxi L (Set 1): Meter with 4 (AA) batteries, optical oxygen probe with 1.5 m cable, storage/calibration bottle, micro SD card with calibration data, software and manual (on Micro SD card), short manual and lanyard in case.
SD 400 Oxi L (Set 2): as Set 1 but with optical oxygen probe with 3 m cable
SD 400 Oxi L (Set 3): as Set 2 but with optical oxygen probe with 10 m cable
Newly developed oxygen meter for use in sewage and water works, research and teaching as well as in aquaristics. High measuring accuracy and low maintenance, thanks to luminescence technology no electrolyte solution is required. The SD 400 Oxi L is ideally suited for the determination of dilution BOD due to the optimized probe for standard BOD bottles.
- Especially high measuring accuracy by luminescence technology
- Short response time of the oxygen probe
- Low maintenance due to long-lasting oxygen probe and membrane head
- Inflow to the oxygen probe is not necessary, the use of stirrers or manual stirring is no longer required
- Includes software for extended and simplified data management with data logger function
- Backlit LC display for dark environments
Scope of delivery:
SD 400 Oxi L (Set 1): Meter with 4 (AA) batteries, optical oxygen probe with 1.5 m cable, storage/calibration bottle, micro SD card with calibration data, software and manual (on Micro SD card), short manual and lanyard in case.
SD 400 Oxi L (Set 2): as Set 1 but with optical oxygen probe with 3 m cable
SD 400 Oxi L (Set 3): as Set 2 but with optical oxygen probe with 10 m cable
Catalogue Number | 6.288 679 |
Manufacturer | Aqualytic |
Manufacturer P/n | 4740010 |
PK | 1 |
Description | SD 400 Oxi L (Set 2) |