Your basket is empty
Home > Laboratory > Analytical Measurement and Testing > Conductivity Measurement > Electrode > IDS conductivity cell probes > Xylem Analytics Germany (WTW) Electrode-IDS Conductivity TetraCon® 925/LV 301718

Xylem Analytics Germany (WTW) Electrode-IDS Conductivity TetraCon® 925/LV 301718
Enlarge

Xylem Analytics Germany (WTW) Electrode-IDS Conductivity TetraCon® 925/LV 301718

PART NO: 4AJ-6269370
Price: €756.00
Out of Stock (Ships in approx. 2 weeks)

with fork design, especially for small volumes, cell constant 0,469 cm-1

Conductivity cell probes
Standard conductivity cell probe TetraCon® 325:
4-pole cell with integral temperature sensor. Cable length 1.5 metres. Measuring range: 1µS/cm to 2µS/cm.

Special conductivity cell probe TetraCon® 325/C:
As TetraCon® 325, 4-pole cell with integral temperature sensor, but with sensor head made of chemically resistant PEEK. Cable length 1.5 metres. Measuring range: 1µS/cm to 2µS/cm

Ultra-pure water conductivity cell probe LR 325/01:
With integral temperature sensor and flowthrough vessel D 01/T for measuring very low conductivity ranges (<1 µS/cm) e.g. boiler feed water or deionised water. Cable length 1.5 metres. Min. / max. insertion depth 35 / 110mm and flowthrough, measuring range: 0.001µS/cm to 200µS/cm.

Conductivity flowthrough cell TetraCon® DU/T:
4-pole conductivity cell with integral temperature sensor for standard applications. Connection via 10mm diameter tubing nozzles (the adapter cable KKDU with 1 metre cable is required for connection). Filling volume 7ml. Measuring range: 1µS/cm to 1000µS/cm.

IDS conductivity cell probe TetraCon® 925:
Intelligent digital 4-pole cell with integral temperature sensor. Automatical transfer of the cell constant. For connection to WTW IDS measuring instruments. Cable length 1.5 metres. Measuring range: 1µS/cm to 2µS/cm.

IDS conductivity cell probe TetraCon® 925/LV:
Intelligent digital 4-pole cell with integral temperature sensor. Fork design, suitable for small volumes (at least 2.5ml) as well as for viscous samples. Automatical transfer of the cell constant. For connection to WTW IDS measuring instruments. Cable length 1.5 metres. Measuring range: 1µS/cm to 2µS/cm.

IDS conductivity cell probe LR 925/01:
Intelligent digital 4-pole cell with integral temperature sensor and flowthrough cell D 01/T for measuring of low conductivity values (<1µS/cm) e.g. in boiler feed water or ion exchange water. Automatical transfer of the cell constant. Cable length 1.5 metres. Min./max. immersion depth 35/110mm and flow through measurement. Measuring range: 0.01µS/cm to 200µS/cm.

Product Specification:
Product Type: TetraCon® 925/LV
Electrode: Graphite
Shaft: Epoxy resin
Length: 120 mm
Cell constant: K = 0.469

Catalogue Number6.269 370
ManufacturerXylem - WTW
Manufacturer P/n301718
Alternative RefTETRACON92
VWR RefGERI30171
ElectrodeGraphite
TypeTetraCon® 925/LV
ShaftEpoxy resin
Cell constantK = 0.469
Length mm120
PK1
Alternative Reference:TETRACON92
VWR:GERI30171
Your basket is empty