Pump drive PD 5201/5206 -High precision even for flow rates starting at 0.005ml/min -Optional foot-pedal remote control via cable to operate pump drive outside a closed fume hood facilitate operation -For the use in cell biology just use a pump head which features convex rollers and does not squeeze the tubing as conventional rollers -All models feature a smooth start operation which prevents spills and splashing media. The speed will ramp up slowly until your set rpm has been reached -Safety for continuous operation: the motor will be switched off if a high thermal load situation occurs to prevent accidents Reproducibility - pumping and dosing -Control the speed (rpm) direction and On/Off via analog interface for 0-10V, 4-20mA or digital RS232 interface -Flow characteristic of pump heads in combination with various tubing diameters is pre-programmed for accurate flow rate numbers -Digital read-out of: Speed (rpm), Tubing diameter, Flow rate in ml/min, Dosing volume, Interval dosing, Pause function -Easily change all process parameters via these buttons -This model connects to an optional foot pedal remote control via cable to start and stop your pump drive outside a closed fume hood increasing your personal safety or easy use in multiple sample fills -This model features electronic speed control and an accuracy of ±0.5% -A press of the max button accelerates the filling and draining of your tube -At the press of a button the pump operates clockwise or counter-clockwise -Calibrate your flow volume and flow rate individually Pumpdrive PD 5201 - Flow rates of 0.3 to 790ml/min with single-channel pump heads -Low speed range from 5rpm to 120rpm -This pump drive is suitable for multi-channel operation -Multi-channel flow rates from 0.005 to 320ml/min -Upgrade your PD 5201 for multi-channel operation in just minutes with a pump head adaptor Pump drive PD 5206 - Flow rates of 1.3 to 3900ml/min with single-channel pump heads -High speed range from 24rpm to 600rpm -This pump drive is not suitable for multi-channel operation The pump head is not included. Please order separately. Product Specification: Product Type: PD 5206 | |
Catalogue Number | 9.829 245 |
Manufacturer | Heidolph |
Manufacturer P/n | 523-52060-00 |
Fisher Ref | 9829245 |
VWR Ref | 224-1355 |
Max. speed 1/min | 600 |
Accuracy speed | ±0.5 % |
IP code | IP 54 |
Power supply | 110 ... 240 V, 50/60 Hz |
Type of auxiliary energy | Mains connection |
Plug type | EU |
Speed | 24 ... 600 1/min |
Flow rate | 2 ... 4056 ml/min |
Depth mm | 256 |
Type | Hei-FLOW Ultimate 600 |
Max. flow rate ml/min | 4056 |
Rated capacity W | 100 |
Width mm | 166 |
Min. speed 1/min | 24.0 |
PK | 1 |
Min. flow rate ml/min | 2.0000 |
Dimensions (WxDxH) | 166 x 256 x 225 mm |
Height mm | 225 |
Weight kg | 7.3 |
Thermo Fisher: | 9829245 |
VWR: | 224-1355 |