Your basket is empty
BROWSE OUR PRODUCT CATALOGUE

How to Achieve More Efficient Flow Control for Bioreactors and Bioprocess Systems


As the need for even more potent and specific pharmaceuticals grows, pharmaceutical manufacturers have turned to biologics to meet increasing needs to solve complex and currently untreatable conditions (including cancer and myriad genetic diseases). Biologics and biosimilars differ from conventional drugs in that they are grown in living cells, rather than manufactured using chemical processes. This growth is carried out in a controlled environment typically termed a bioreactor or fermenter. The bioreactor environment poses some unique challenges to process and automation experts. The bioprocessing techniques required utilize sophisticated control schemes, specific materials and complex gas control systems. As the organisms grow, mass flow needs within the reactor can scale exponentially, more than in most common chemical and industrial processes.

Alicat Bioreactors

The diagram shows a typical gas input schema or a global premier biologics manufacturer. Note that this design requires high flow and low flow lines for both oxygen and process air.  This multiplicity of mass flow lines shown is required by the limited controllable range of the mass flow controllers used. For example, the oxygen flow lines show one controller to be used for flow rates under 35 SLPM and another for flow rates under 100 SLPM. These flow ranges imply a controllable range of no more than 50:1 for the controller specified. Alicat recommended that this design could be simplified by utilizing Alicat’s mass flow controllers. The latest Alicat mass flow controllers have a controllable range of up to 10:000:1, far more than the 30:1 requiring a dual flow range design and improved from the 200:1 previously available.

Alicat Bioreactors

Bioreactors typically have feed pressures of approximately 50 Psig or less. Table 1 shows the flow rate error of a standard Alicat BIO series 10 SLPM (Standard Litres per Minute) controller when turned down from 10 SLPM to 1 SCCM under typical conditions.

Alicat Bioreactors

Virtually any modern mass flow controller can be adequate within the middle and top of their specified flow range, regardless of the measurement technology used. The Alicat mass flow controller has a mass flow error of only 0.6% near the top of the scale, and only 1% error at 1 SLPM. What enables the flow range simplification discussed is the high degree of accuracy at very low flows. An Alicat MFC has an error of less than 10% of the desired flow rate down to a turndown of 100:1. Even as low as 1000:1 the error in flow is only 0.01 SLPM for a 10 SLPM flow controller. The data indicates that this biologics manufacturer could reduce the total lines needed for this design from 5 lines to 3 by using an Alicat mass flow controller with a differential pressure-based measurement technique. This allows for a 33% cost savings in parts, construction time and control systems for this portion of the bioreactor. All the while simplifying the design, increasing redundancy and decreasing the number of potential failure points.

Many of the above advantages are enabled by Alicat’s laminar flow measurement technology. In addition to providing very high controllable ranges, this technology is also equally accurate for any gas controlled; there is no need for imprecise K factors or other compensation techniques. This means fewer spares are needed, since any unit can work equally well with any gas. Changing gases via Alicat’s “gas select” feature is easily done from the unit’s front touchscreen. All with no loss of accuracy or need for re-calibration. 

Other mass flow controllers commonly use thermal measurement technology.  While this method has stood the test of time (dating back to 1911), thermal units cannot respond quickly, as the sensor mass needs to change in temperature to change reading. While newer thermal designs respond faster due to predictive algorithms, Alicat’s differential pressure method can respond to control changes as fast as 25ms – about 50X faster. Thermal units are also sensitive to process water contamination, as the presence of water effects the measurement and calibration of the heated flow sensor. Alicat mass flow technology is relatively insensitive to transient contamination with water (see our previous experiment demonstrating this).

Alicat’s mass flow controllers and meters also provide other features enabling superior accuracy and ease of use. Units can be calibrated either in place, or on-site, using available Alicat software and calibration standards. This calibration procedure is the same regardless of how the units are controlled; analogue, digital or via industrial protocol. Under these same conditions, an Alicat flow controller can also report multiple parameters, simultaneously. For example, an Alicat flow controller can output mass flow, pressure, valve drive voltage and temperature – all at the same time.  For ease of troubleshooting and testing, units also have a built in full colour TFT display that can be rotated 180 degrees, as well as control via a built-in keypad.

Alicat Bioreactors

Alicat’s controllers and meters enable simple and efficient designs. And the Bio series does so with options for a fully BPE compliant design, certified USP VI elastomers, your choice of industrial protocol and much, much more. Choose the unprecedented controllable range in the latest Alicat series mass flow controllers and meters to reduce your bioprocessing costs while increasing system performance and improving reliability.

Want to Know More?

Contact us today to find out more about bioreactors and bioprocessing. Our team will be happy to help with any queries you may have.

Contact us Today!

 

Copyright 2013 Lab Unlimited Sitemap | Terms & Conditions | ! Product images are for illustrative purposes only !