Your basket is empty
BROWSE OUR PRODUCT CATALOGUE

Humidity Chambers HCP

The Memmert humidity chamber HCP - This climate chamber offers a full range of comfort, reliability and safety. This humidity chamber is ideally suited for environmental testing, environmental simulation, accelerated service life tests and 85/85 tests according to IEC 60068-2-67 and IEC 60068-2-78.
The active humidity control is the guarantee for ideal homogeneity of temperature and humidity as well as for short recovery times after opening the door. In combination with heating on all six sides, including heated inner glass door, it also minimises vaporisation in the interior and thus the risk of condensed water dripping onto the test object. An aluminium thermal conductive layer supports optimum temperature distribution and serves as a heat accumulator in case of a temporary power failure.

Model variant TwinDISPLAY: ControlCOCKPIT with two colour displays
You can find a detailed description of the "TwinDISPLAY" model at www.memmert.com

Humidity Chambers HCP
Specifications
Setting range active humidity control:20 to 95 % rh
Setting accurate humidity:0.5 % rh
Working temperature range:at least 7 °C above ambient up to +90 °C
Setting temperature range:+18 °C to +90 °C
Setting accurate temperature:0.1 °C
Power supply:230 V, 50/60 Hz

Humidity Chambers HCP



Memmert Humidity chamber HCP 150 HCP 150
PART NO.4AJ-4662065
77600||76721||77224||77542||77352||77525||78099||78300||78334||78065
Type||Nominal capacity l||Shelf support ribs/shelves||Max. grids||Included shelves||Internal dimensions (W x D x H) mm||External dimensions (W x D x H) mm||Rated capacity kW||Weight kg||PK
HCP150||156||10/2||10||2||560 x 400* x 700||719 x 591** x 1070||1.8||90||1
Memmert
HCP 150

Climate chambers

Humidity chambers

0
5
2
1
Out of Stock
Memmert Humidity chamber HCP 105 HCP 105
PART NO.4AJ-4662064
77600||76721||77224||77542||77352||77525||78099||78300||78334||78065
Type||Nominal capacity l||Shelf support ribs/shelves||Max. grids||Included shelves||Internal dimensions (W x D x H) mm||External dimensions (W x D x H) mm||Rated capacity kW||Weight kg||PK
HCP105||107||6/2||6||2||560 x 400* x 480||719 x 591** x 850||1.72||75||1
Memmert
HCP 105

Climate chambers

Humidity chambers

0
7
1
1
Out of Stock
Memmert Humidity chamber HCP 50 HCP 50
PART NO.4AJ-4662063
77600||76721||77224||77542||77352||77525||78099||78300||78334||78065
Type||Nominal capacity l||Shelf support ribs/shelves||Max. grids||Included shelves||Internal dimensions (W x D x H) mm||External dimensions (W x D x H) mm||Rated capacity kW||Weight kg||PK
HCP50||56||5/1||5||1||400 x 330* x 425||559 x 521** x 795||1.52||55||1
Memmert
HCP 50

Climate chambers

Humidity chambers

0
6
0
1
Out of Stock
Memmert Humidity chamber HCP 240 HCP 240
PART NO.4AJ-4662066
77600||76721||77224||77542||77352||77525||78099||78300||78334||78065
Type||Nominal capacity l||Shelf support ribs/shelves||Max. grids||Included shelves||Internal dimensions (W x D x H) mm||External dimensions (W x D x H) mm||Rated capacity kW||Weight kg||PK
HCP240||241||12/2||12||2||600 x 500* x 810||759 x 691** x 1180||1.84||110||1
Memmert
HCP 240

Climate chambers

Humidity chambers

0
5
3
1
Out of Stock

Copyright 2013 Lab Unlimited Sitemap | Terms & Conditions | ! Product images are for illustrative purposes only !