Your basket is empty
BROWSE OUR PRODUCT CATALOGUE

Dissolved oxygen meter Seven2Go™ pro S9

Portable professional model for dissolved oxygen measurement.

  • New, intuitive menu structure with fast and easy T-Pad navigation
  • Robust design with IP67 protection for use in harsh and demanding environments
  • Intelligent Sensor Management (ISM®) functionality reduces the risk of errors
  • New sunlight-proof screen guarantees screen readability even in direct sunlight
  • New StatusLight gives a fast, visual confirmation showing if the meter is ready to measure or not
  • Operating support for 12 languages with information shown in complete words and sentence
  • Up to 2 calibration points and a choice of 2 predefined oxygen standards
  • Automatic, manual and time dependant endpoint recording
  • Data memory storage for 2000 GLP data points with weatherproof Micro-USB connection for data export
  • Power requirements: 4 x 1.5 V AA or 1.3 V NiMH accumulators

Scope of supply:
S9-Meter: Includes instrument, LabX® direct pH, USB cable, electrode clip, base accessory, operating instructions, quick guide, test certificate, declaration of conformity, batteries
S9-Standard kit: As S9-Meter, but also with InLab® OptiOx™, zero oxygen tablets
S9-Field kit: As S9-Standard kit, but also with bottles for calibration, uGo™ carrying case, InLab® OptiOx™ with protective guard
S9-BOD kit: As S9-Field kit, but including InLab® OptiOx™ (without protective guard), BOD adapter, BOD application note

Dissolved oxygen meter Seven2Go™ pro S9

Dissolved oxygen meter Seven2Go™ pro S9



Seven2Go Rdo-S9-Field-Kit 30207972 Mettler
PART NO.4AJ-6265265
79556||79252||81950||81414||81402||81174||81398||79125||82272||79279||79384||82030||81462||79898||81973||81069||81046||81311||81967||78960||79404||81657
Power supply||With stopcock||Max. stat. load capacity||Saturation accuracy||Min. width labels||Max. relative humidity||Temperature||Test force||Min. voltage V||Depth stage mm||Max. measuring frequency||Volume vessel||Width mm||Depth mm||Height mm||Max. heating rate||Readability HD||Material stopcock||Material column||Min. filter Ø||IP code||PK
S9-Field kit||0.01 mg/l (ppm)||±0.1 mg/l (0 ... 8 mg/l)/±0.2 mg/l (8 ... 20 mg/l)/±10 % (20 ... 50 mg/l)||0.1 ... 500.0 %||0.1 %||±10 %||1 mbar||±2 %||0||50||0 ... 50 °C||±0.1 °C||70||35||222||70 x 35 x 222 mm||290|| ||4 x 1.5 V, AA||IP 67||1
Mettler
30207972

Oxygen meters

Oxymeters

0
1
2
1
Out of Stock
Seven2Go Rdo-S9-Standard-Kit 30207971 Mettler
PART NO.4AJ-6265264
79556||79252||81950||81414||81402||81174||81398||79125||82272||79279||79384||82030||81462||79898||81973||81069||81046||81311||81967||78960||79404||81657
Power supply||With stopcock||Max. stat. load capacity||Saturation accuracy||Min. width labels||Max. relative humidity||Temperature||Test force||Min. voltage V||Depth stage mm||Max. measuring frequency||Volume vessel||Width mm||Depth mm||Height mm||Max. heating rate||Readability HD||Material stopcock||Material column||Min. filter Ø||IP code||PK
S9-Standard kit||0.01 mg/l (ppm)||±0.1 mg/l (0 ... 8 mg/l)/±0.2 mg/l (8 ... 20 mg/l)/±10 % (20 ... 50 mg/l)||0.1 ... 500.0 %||0.1 %||±10 %||1 mbar||±2 %||0||50||0 ... 50 °C||±0.1 °C||70||35||222||70 x 35 x 222 mm||290|| ||4 x 1.5 V, AA||IP 67||1
Mettler
30207971

Oxygen meters

Oxymeters

0
1
1
1
Out of Stock
Seven2Go Rdo-Meter S9 30207970 Mettler
PART NO.4AJ-6265263
79556||79252||81950||81414||81402||81174||81398||79125||82272||79279||79384||82030||81462||79898||81973||81069||81046||81311||81967||78960||79404||81657
Power supply||With stopcock||Max. stat. load capacity||Saturation accuracy||Min. width labels||Max. relative humidity||Temperature||Test force||Min. voltage V||Depth stage mm||Max. measuring frequency||Volume vessel||Width mm||Depth mm||Height mm||Max. heating rate||Readability HD||Material stopcock||Material column||Min. filter Ø||IP code||PK
S9-Meter||0.01 mg/l (ppm)||±0.1 mg/l (0 ... 8 mg/l)/±0.2 mg/l (8 ... 20 mg/l)/±10 % (20 ... 50 mg/l)||0.1 ... 500.0 %||0.1 %||±10 %||1 mbar||±2 %||0||50||0 ... 50 °C||±0.1 °C||70||35||222||70 x 35 x 222 mm||290|| ||4 x 1.5 V, AA||IP 67||1
Mettler
30207970

Oxygen meters

Oxymeters

0
4
0
1
Out of Stock
Seven2Go Rdo-S9-Bod-Kit 30207939 Mettler
PART NO.4AJ-6265266
79556||79252||81950||81414||81402||81174||81398||79125||82272||79279||79384||82030||81462||79898||81973||81069||81046||81311||81967||78960||79404||81657
Power supply||With stopcock||Max. stat. load capacity||Saturation accuracy||Min. width labels||Max. relative humidity||Temperature||Test force||Min. voltage V||Depth stage mm||Max. measuring frequency||Volume vessel||Width mm||Depth mm||Height mm||Max. heating rate||Readability HD||Material stopcock||Material column||Min. filter Ø||IP code||PK
S9-BOD kit||0.01 mg/l (ppm)||±0.1 mg/l (0 ... 8 mg/l)/±0.2 mg/l (8 ... 20 mg/l)/±10 % (20 ... 50 mg/l)||0.1 ... 500.0 %||0.1 %||±10 %||1 mbar||±2 %||0||50||0 ... 50 °C||±0.1 °C||70||35||222||70 x 35 x 222 mm||290|| ||4 x 1.5 V, AA||IP 67||1
Mettler
30207939

Oxygen meters

Oxymeters

0
0
3
1
Out of Stock

Copyright 2013 Lab Unlimited Sitemap | Terms & Conditions | ! Product images are for illustrative purposes only !