PTV 6000 Online Turbidity Meter Laser EPA
Enlarge

PTV 6000 Online Turbidity Meter Laser EPA

PART NO: 6-615

The PTV 6000 Process Turbidity Meter is a Class 1 Laser product which possess highly improved optical qualities to yield a very stable process measurement system. The enhanced stability of the PVT 6000 provides additional information that can be deciphered from the laser turbidity measurement and used as a separate parameter to further improve the limit of detection. This product includes an interlocked, non-serviceable, Class 3B laser. The two interlocks ensure that the user is safe and not exposed to the laser radiation. The PVT 6000 has additional features such as:

  • A drift compensated solid state laser of 685 nm
  • Limit of detection better than 0.0001 NTU
  • Range 0.0001 to 20.00 NTU
  • Laser safety interlock system
  • High sensitivity to small turbidity events
  • RSD Parameter for the prediction of breakthrough events
  • Excels at membrane filtration processes for drinking water, ultra pure water and any clean water purity monitoring

RSD Parameter:

The RSD parameter has been shown to enhance the sensitivity of detection through minor breakthroughs in different filtration systems. The use of the RSD parameter as a predictive indicator of pending filtration breakthrough requires an optical arrangement where a portion of a sample is interrogated by a beam of light with high energy density such as a laser. This makes the product capable of detecting the presence of particles in very low concentrations. Compared to a standard conventional turbidity meter which can only detect particles of 1.0 µm or larger, the PTV 6000 can observe particles of as small as 0.01- µm.

The RSD parameter in the PTV 6000 can be automatically viewed on the instruments touchscreen as well on mobile devices which are connected to the device itself. This makes feedback easy and accessible as the parameter should be based on each water treatment plants design and operational parameters.

Regulatory Compliant:

The PTV Series has instruments that meet EPA and ISO regulatory requirements. The instrument can easily be configured with additional features such as integrated flow indication, digital communication protocols and Bluetooth® connectivity. Everything the users need for calibration and verification protocols as well as other key accessories to provide a single source for turbidity measurement are supplied by Lovibond Tintometer. 


Specifications:

  • Measurement Method: Nephelometry, scattered light collected at 90° to the incident beam
  • Operating temperature: 0 to 50°C (32 to 122°F)
  • Measurement Range: 0.0001 to 20.00
  • Display units: FNU, NTU, mNTU, TE/F, mg/l PSL, mg/l Kaolin, Degree, custom
  • Accuracy: ± 2% of reading from 0 to 10 NTU, ± 4% of reading between 10 to 100 NTU
  • Repeatability: Less than 1% at 1 NTU/FNU, expressed as percent relative standard deviation (%RSD)
  • Linearity error: Less than 1% for 0 to 5 NTU and 2% for turbidity values greater than 10 NTU (requires 2-point calibration)
  • Stray Light: <0.005 / 5 mNTU
  • Limit of Detection: <0.0001 NTU
  • Limit of Quantitation: Better than 0.001 NTU
  • Resolution: 0.0001 NTU or FNU (range dependent 5 digits displayed)
  • Response time: 10% change within 40 seconds @ 200 mL/min
  • Response: 10 to 90% Less than 240 seconds @ 200 mL/min at 1 NTU
  • Signal Averaging User Selectable: 1, 3, 6, 10, 30, 60, and 90 seconds, default set to 30 seconds
  • Sample temperature: 0 to 50°C (32 to 122°F)
  • Sample Flow: 30 to 500 2 mL/min (0.476 to 7.925 gal/hr),40 to 120 mL/min (0.634 to 1.902 gal/hr) recommended flow; 2
  • For flow rates above 100 ml/min (1.585 gal/hr) use external flow monitoring (not supplied)
  • Sample pressure: 0.03 to 5.5 bar (0.435 to 80 psi)
  • Sample Volume: 285-ml (Measurement Module installed in Flow Body)
  • Humidity: 5 to 95 %RH (Non-condensing)
  • Regulatory: IS0 7027: PTV 1000 IR
  • Compliance Methods: EPA: PTV 1000 WL, PTV 2000 & PTV 6000
  • Safety Compliance PTV 6000: Class 1 laser product, contains non-serviceable laser operating at 685 ± 10 nm, 55mW max output.
  • Alarms: Three set-point alarms, each equipped with an SPDT relay with unpowered contacts rated 5A resistive load at 230 VAC
  • Pollution degree: 2
  • Enclosure rating: IP 65
  • Mounting: Indoor using supplied quick-connect mounting cleat affixed to a wall. Optional Panel Mount accessory is available
  • Dimensions HxDxW: 34.0 x 13.7 x 20.3 cm (13.4 x 5.4 x 5.8 in)
  • Shipping weight: 1 kg (2.2 lbs)
  • Method of calibration: 1-point calibration defaulted to a value of 5.0 NTU with any regulatory approved formazin calibrant.
  • Sensor cable length Standard: 0.6 m (~2 ft)
  • Optional: 2, 3 and 10 m (6.6, 9.8 and 32.8 ft)
  • Storage and shipping temperature: -40° to 60°C (-40 to 140°F)
  • Power requirements: 24 VDC, 1.5A supplied by PCM
  • Inlet fitting: ¼-inch NPT female, ¼-inch quick-connect tubing (Included) (¼ inch = 6 mm)
  • Outlet fitting: 3/8-inch NPT female,3/8-inch hose barb tubing (Included) (3/8-inch = 9mm)
  • Sample tubing: HDPE, ¼-inch OD (high-density polyethylene), color = black or blue (¼ inch = 6 mm)
  • Analog output: Two outputs selectable range of 0-20 mA or 4-20mA; Output programmable over any portion of the measurement range.
  • Connections inside PCM.
  • Interface protocols: Touch screen USB to Android or Windows device via PCM.
  • Wireless (Regional Availability): Low Energy Bluetooth® between
  • Measurement Module and Smart Device (iOS or Android)
  • Dry Verification: Device (high or low value)
  • Wet Verification: T-CALplus®, T-CAL® or Formazin
  • Calibration options: T-CALplus®, T-CAL® or Formazin: 1-point calibration (5.0 NTU recommended; or between 4 to 22 NTU)
  • RSD Parameter: For measurement of baseline fluctuation
  • Warranty: 1 year